Valve body, valve cover:HT200、ZG230-450、ZG1Cr18Ni9Ti
spool:ZG1Cr18Ni9Ti、Our surfacing Stellite Alloys Reinforced PTFE
Packing: PTFE, flexible graphite
Push rod, bushing:2Cr13
Gasket: asbestos rubber sheet、10、1Cr18Ni9Ti Asbestos gasket
corrugated pipe:1Cr18Ni9Ti
Regulating range:
|
Regulating range CN(mm) |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
||
|
Valve seat diameter DN(mm) |
1.6 4.0 |
||||||||||||||
|
Rated flow coefficient Kv |
Single seat |
5 |
7 |
11 |
20 |
30 |
48 |
75 |
120 |
190 |
300 |
480 |
760 |
1100 |
|
|
Two seater |
|
|
12 |
22 |
33 |
53 |
83 |
132 |
209 |
330 |
528 |
836 |
1210 |
||
|
Sleeve |
|
|
11 |
20 |
30 |
48 |
75 |
120 |
190 |
300 |
480 |
760 |
1100 |
||
|
Rated travel(mm) |
6 |
8 |
10 |
14 |
20 |
35 |
|||||||||
|
Allowable differential pressure Mpa) |
1.6 |
1.5 |
0.5 |
||||||||||||
|
Temperature regulating range(℃) |
10-20、20-40、30-50、40-50、50-60、60-70、70-80、80-100………180-200 |
||||||||||||||
|
Adjustment precision(%) |
±5 |
||||||||||||||
|
Allowable overload value(℃) |
Respectively, the temperature adjustment range50 |
||||||||||||||
|
Using ambient temperature(℃) |
-40~±80 |
||||||||||||||
|
Mounting joint |
G1 |
||||||||||||||
|
Capillary length(m) |
3、5 |
||||||||||||||
|
Allowable leakage |
Hard seal(1/h) |
Two seater, sleeve: 5 x 10 - 3 x 10: single seat valve rated capacity, rated capacity of 4 * - valve |
|||||||||||||
|
Soft seal(ml/min) |
0.15 |
0.15 |
0.15 |
0.30 |
0.30 |
0.45 |
0.60 |
0.90 |
1.70 |
4.0 |
4.0 |
6.75 |
11.10 |
||
Main parameters are shown in Table 1.:
|
Nominal diameter CN(mm) |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
||
|
Valve seat diameter DN(mm) |
1.6 4.0 |
||||||||||||||
|
Rated flow coefficient Kv |
Single seat |
5 |
7 |
11 |
20 |
30 |
48 |
75 |
120 |
190 |
300 |
480 |
760 |
1100 |
|
|
Two seater |
|
|
12 |
22 |
33 |
53 |
83 |
132 |
209 |
330 |
528 |
836 |
1210 |
||
|
Sleeve |
|
|
11 |
20 |
30 |
48 |
75 |
120 |
190 |
300 |
480 |
760 |
1100 |
||
|
Rated travel(mm) |
6 |
8 |
10 |
14 |
20 |
35 |
|
||||||||
|
Allowable differential pressure Mpa) |
1.6 |
1.5 |
0.5 |
||||||||||||
|
Temperature regulating range(℃) |
0~70、50~120、100~170、150~220、200~270 |
||||||||||||||
|
Adjustment precision(%) |
±5 |
||||||||||||||
|
Allowable overload value(℃) |
Respectively, the temperature adjustment range50 |
||||||||||||||
|
Using ambient temperature(℃) |
-40~±80 |
||||||||||||||
|
Mounting joint |
G1 |
||||||||||||||
|
Capillary length(m) |
3、5 |
||||||||||||||
|
Allowable leakage |
Hard seal(1/h) |
Two seater, sleeve: 5 x 10 - 3 x 10: single seat valve rated capacity, rated capacity of 4 * - valve |
|||||||||||||
|
Soft seal(ml/min) |
0.15 |
0.15 |
0.15 |
0.30 |
0.30 |
0.45 |
0.60 |
0.90 |
1.70 |
4.0 |
4.0 |
6.75 |
11.10 |
||
|
Nominal diameter(DN) |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
|
H |
500 |
540 |
580 |
640 |
700 |
750 |
820 |
950 |
1100 |
1280 |
|||
|
T |
235、430 |
430、630 |
630、1000 |
||||||||||
|
h |
350 |
||||||||||||
|
d |
25 |
||||||||||||
|
Protective sleeve diameter |
ф28 |
||||||||||||
|
weight(kg) |
8 |
10 |
13 |
15 |
18 |
30 |
35 |
60 |
75 |
85 |
110 |
150 |
|
|
Nominal diameter DN(mm) (Valve seat diameter dn) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
|||||
|
(10) |
(12) |
(15) |
(20) |
|||||||||||||
|
Rated flow coefficient |
Straight grade |
1.8 |
2.8 |
4.4 |
6.9 |
11 |
17.6 |
27.5 |
44 |
69 |
110 |
176 |
275 |
440 |
690 |
|
|
Equal percentage |
1.6 |
2.5 |
4 |
6.3 |
10 |
16 |
25 |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
||
|
Rated travel(mm) |
16 |
25 |
40 |
60 |
||||||||||||
|
Nominal pressure PN(MPa) |
1.0 1.6 4.0 6.4 |
|||||||||||||||
|
Inherent flow characteristic |
Linear, equal percentage |
|||||||||||||||
|
Inherently adjustable ratio |
50 |
|||||||||||||||
|
Allowable leakage |
Single seat |
Hard seal:IV Soft seal:VI level |
||||||||||||||
|
|
Sleeve |
Hard seal:II level Soft seal:VI level |
||||||||||||||
|
working temperature t(℃) |
-20~200 -40~250 -40~450 -60~450 |
|||||||||||||||
|
Signal range(mA.DC) |
0~10 4~20 |
|||||||||||||||
|
Mode of action |
Electric closed type electric open type |
|||||||||||||||
|
Using ambient temperature(℃) |
Electric control valve:-20~70℃ |
|||||||||||||||
|
Using environmental humidity |
Electric control valve:≤95% |
|||||||||||||||
|
supply voltage |
220V 50Hz |
|||||||||||||||
简体中文版
English